Telescope control
The RCC telescope can be controlled from m5
. To access the computer, you can use ssh
, for example:
ssh -X user@m5.konkoly.hu
where user is your username on m5
For observing, it is advised to use the screen
utility, see its description here: Usage of the screen program
As an alternative to ssh
, you can use X2GO, which gives you remote access to the graphical user interface. See its description here: Usage of X2GO
The EMCCD camera can be controlled from a GUI. The basic telescope control is the same as with the other instruments, see also Usage of the SI 1100S on the RCC.
Before starting the observations, check the status of the subsystems from the console with:
rcc-test
If everything is green, proceed further. If not, contact the support astronomer.
Check the position of the pickoff mirror from the console with:
acectrl --status
If Main pickoff mirror is off, the telescope is ready for photometric observations. If not, type acectrl --stop
.
Start ds9
.
Check the telescope: http://ccdsh.konkoly.hu/static/tmp/prcc-state.html?refresh=60
Start CCDSH in a console, preferably from screen
:
ccdsh
Type CCD>
status
in CCDSH. If everything is green, proceed further.
If you intend to use guiding, cool the guider camera. Type in a console:
rcc-autoguide.qsi --temperature -20
-15 recommended during summer.
Open the dome slit. In CCDSH:
CCD>
set dome slit open
Start the tracking:
CCD>
set mount track on
Start the automatic dome rotation:
CCD>
rcc dome auto
Open the tube and mirror covers:
CCD>
rcc tubecover open
After 30 seconds:
CCD>
rcc mirrorcover open
Type CCD>
rcc status
. If everything is opened and green, proceed.
Using OCELOT
OCELOT itself can be controlled via a GUI, therefore the optimal way to reach the controlling computer (in case of the RCC) m16
is by VNC protocol, e.g.:
xvncviewer -bgr233 -via root@m16 :42
m16
can only be reached from the internal network. There is only root login, contact the support astronomer for the password. Screen 42 should be used. The switch bgr233
reduces the color depth resulting in lower latency.
On m16
, the program ixon-server
should always be running. Usually, the user does not have to start it. In case of a power failure, or software crash, it can be started with the command (via screen
)
ixon-server /usr/local/etc/ixon-server/ixon-server.cfg
If the ixon-server
cannot be started this way due to a lock-file in /tmp
, but you are absolutely sure that the server is not running (try e.g. ps aux | grep ixon-server
), the lock file can safely be removed. After the removal, the server will likely start. This problem is usually present if the ixon-server suddenly halts (i.e. not properly shut down), mostly due to a power failure, or a rare case of segmentation fault.
Before restarting m16
, the ixon-server
has to be stopped properly. It can be carried out via telnet:
telnet localhost 32768
After connecting to the server, the command shutdown
stops the server itself. The connection can be terminated by closeconn
. Do this only, if you are absolutely sure about the results!
The camera controlling program can be started by the following command:
ixon-gui
The FITS viewing program ds9
has to be started by the user as well. A typical screen of ixon-gui
can be seen below.
First of all, the connection can be established by pressing the Connect
button at the lower-left corner of the window. The camera cooling can be controlled via the the Set Temp
input field. Note that the power usage of the cooler is not indicated explicitly. If the current temperature is indicated by blue numbers, then the temperature set can be hold safely. Without the water cooler, a temperature of -80 °C can be reached. In wintertime, when the external temperature in the dome is below 5 °C, and the Case Fan is set to operate between 9.0-19.0 °C, a stable -90 °C temperature can be reached with air cooling. With the circulatory system installed, the threshold is around -100 °C.
On the CCD Readout Control
section on the above figure typical settings are shown. Change these only if you are certain about what you are doing!
The camera can be used in non-EM mode as well, in this case, the Output Amp
field should be set to Conventional
. Otherwise, set it to EM
. The typical value of the EM gain
is 40.
For dark frames, the field Shutter mode
should be set to closed. The exposure time is given in milliseconds. Also note that the lowest achievable time depends on the trimming (it can be set in the input fields Image Size
) and the binning. 2x2 binning is resonable to use in most cases. While doing lucky imaging 1x1 binning might be a better choice.
Observing sequences can be defined on the panel Observing Blocks
in a self-explanatory way. In the ixon-gui
, the filter field should be left on U. The filters can be set via the program acectrl
running on m5
. In the spectrograph frontend, there are two built-in filter wheels.
Filters
Currently a 80x80mm Johnson-Cousins BVRI set is installed at the first (#1) wheel while a partial series of 50x50mm Sloan filters are installed in the second (#2) wheel. The filters can be changed and specified in ixon-gui
on the Observing blocks panel, or with the following command from the terminal:
acectrl --filter-1 n
where n indicates the number of the filter:
- 0: empty - 1: B - 2: V - 3: R - 4: I - 5: clear
The second wheel can be changed accordingly, i.e.
acectrl --filter-2 n
where n indicates the number of the filter:
- 0: empty - 1: empty - 2: empty - 3: Sloan r' - 4: Sloan i' - 5: Sloan z'
For a more detailed description of acectrl
, see article ACE spectrograph.
Please note that the two filter wheels located above each other. Hence, one should set the second wheel to "empty" state if a filter from the first wheel is used and vice versa. Note that acectrl
is a low-level control program in this sense. Using ixon-gui
, this is done automatically.
Focus
Note that the focus of the telescope can be adjusted from ccdsh
on the regular way:
set focus n
where n is the focus value. For the EMCCD/OCELOT, the default is around 79.8 without the Barlow lens.
Flat fielding
To make flat frames, you should open the tube and mirror covers and turn off the dome lights. Depending on what filter you would like to use, turn on the appropriate flat lamp.
In a console:
energenie-manage --flat-faint on
Or:
energenie-manage --flat-bright on
Or:
energenie-manage --flat-dimm on
Turn the telescope to the flat screen from CCDSH:
CCD>
set dome azimuth=156.3
and CCD>
rcc slew 7 -4.5
Always check the exposure times for the flats. A good flat is around 20000-30000 ADU.
When you finished, turn off the flat lamp(s). In a console:
energenie-manage --flat-faint off
, etc.
REVISE THE TABLE!
The following two tables contain some guidance for setting exposure times of flat field images. Note however, that at Piszkéstető, the observer always has to assume that the flat lamps have been moved (due to demonic possession, events only relevant on quantum levels, etc.), despite the large sign on the lamps saying "do not move the flat lamps, in fact do not even think about it". Therefore, these values have to be confirmed before a long sequence of flat field images.
Table for T=-70 C, AD converter setting 16bit, 1024x1024px image size, 1x1 bin. The pixel values are in the interval of 20k-40k ADU.
Conventional (bright) | Conventional (faint) | EM=5 (bright) | EM=5 (faint) | EM=20 (bright) | EM=20 (faint) | |
---|---|---|---|---|---|---|
Johnson B | 45 | - | 35 | - | 10 | 180 |
Johnson V | 5 | 60 | 5 | 60 | 1 | 15 |
Johson R | 1 | 15 | 1 | 10 | 0.3 | 3 |
Johnson I | 0.3 | 3 | 0.3 | 3 | 0.1 | 1 |
Sloan r' | 1 | 15 | 1 | 10 | 0.3 | 3 |
Sloan i' | 0.5 | 5 | 0.3 | 4 | 0.1 | 1 |
Sloan z' | 0.5 | 5 | 0.3 | 3 | 0.1 | 1 |
Clear | 0.2 | 2 | 0.2 | 2 | 0.1 | 0.5 |
Empty | 0.2 | 2 | 0.2 | 2 | 0.1 | 0.5 |
Table for T=-70 C, AD converter setting 16bit, 1024x1024px image size, 2x2 bin. The pixel values are in the interval of 20k-40k ADU.
Conventional (bright) | Conventional (faint) | EM=5 (bright) | EM=5 (faint) | EM=20 (bright) | EM=20 (faint) | |
---|---|---|---|---|---|---|
Johnson B | 15 | 120 | 10 | 120 | - | 45 |
Johnson V | 2 | 20 | 1 | 15 | - | 5 |
Johnson R | 0.5 | 3 | 0.3 | 13 | - | 1 |
Johnson I | 0.1 | 1 | 0.1 | 1 | - | 0.2 |
Sloan r' | 0.3 | 3 | 0.3 | 3 | - | 1 |
Sloan i' | 0.1 | 1 | 0.1 | 1 | - | 0.3 |
Sloan z' | 0.1 | 1 | 0.1 | 1 | - | 0.3 |
Clear | 0.05 | 0.5 | 0.05 | 0.3 | - | 0.1 |
Empty | 0.05 | 0.5 | 0.05 | 0.3 | - | 0.1 |
|